Resultados 1 - 20 de 140
Filtrar
1.
Arch Pathol Lab Med ; 148(2): 139-148, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37776255

RESUMO

CONTEXT.­: The Sustainable Predictive Oncology Therapeutics and Diagnostics quality assurance pilot study (SPOT/Dx pilot) on molecular oncology next-generation sequencing (NGS) reportedly demonstrated performance limitations of NGS laboratory-developed tests, including discrepancies with a US Food and Drug Administration-approved companion diagnostic. The SPOT/Dx pilot methods differ from those used in proficiency testing (PT) programs. OBJECTIVE.­: To reanalyze SPOT/Dx pilot data using PT program methods and compare to PT program data.Also see p. 136. DESIGN.­: The College of American Pathologists (CAP) Molecular Oncology Committee reanalyzed SPOT/Dx pilot data applying PT program methods, adjusting for confounding conditions, and compared them to CAP NGS PT program performance (2019-2022). RESULTS.­: Overall detection rates of KRAS and NRAS single-nucleotide variants (SNVs) and multinucleotide variants (MNVs) by SPOT/Dx pilot laboratories were 96.8% (716 of 740) and 81.1% (129 of 159), respectively. In CAP PT programs, the overall detection rates for the same SNVs and MNVs were 97.2% (2671 of 2748) and 91.8% (1853 of 2019), respectively. In 2022, the overall detection rate for 5 KRAS and NRAS MNVs in CAP PT programs was 97.3% (1161 of 1193). CONCLUSIONS.­: CAP PT program data demonstrate that laboratories consistently have high detection rates for KRAS and NRAS variants. The SPOT/Dx pilot has multiple design and analytic differences with established PT programs. Reanalyzed pilot data that adjust for confounding conditions demonstrate that laboratories proficiently detect SNVs and less successfully detect rare to never-observed MNVs. The SPOT/Dx pilot results are not generalizable to all molecular oncology testing and should not be used to market products or change policy affecting all molecular oncology testing.


Assuntos
Laboratórios , Proteínas Proto-Oncogênicas p21(ras) , Humanos , Proteínas Proto-Oncogênicas p21(ras)/genética , Patologistas , Projetos Piloto , Ensaio de Proficiência Laboratorial/métodos , Proteínas de Membrana , GTP Fosfo-Hidrolases/genética
2.
PLoS One ; 18(3): e0282650, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36897841

RESUMO

BACKGROUND: Proficiency testing (PT) has been hard to set up due to cost limitations and technical capacity. Conventional Xpert MTB/RIF PT programs use liquid and culture spots which require stringent storage and transportation conditions with cross-contamination chances prevalent. These setbacks prompted the use of dried tube specimens (DTS) for Ultra assay PT. For continuity of PT provision, stability of DTS and compatibility with testing protocols when kept for a long period needs to be established. METHODS: DTS were prepared from known isolates inactivated using a hot air oven at 85°C. 100µl of bacterial suspensions were aliquoted and dried inside a Biosafety cabinet. Panel validation was done to establish the baseline Deoxyribonucleic acid (DNA) concentration in terms of cycle threshold (Ct) value. DTS aliquots were shipped to participants to test and report within six weeks. The remaining DTS were kept at 2-8°C and room temperature for one year with testing at six months. Twenty (20) DTS samples per set remaining at one year were heated at 55°C for two weeks before testing. The means of the different samples were compared to validation data using paired t-tests. Boxplots were designed to visualize the differences in the medians of the DTS. RESULTS: Overall mean Ct value increased by 4.4 from the validation to testing after one year at the different storage conditions. Samples heated at 55°C showed a 6.4 Ct difference from validation data. Testing done at six months on 2-8°C stored items showed no statistical difference. At all the remaining testing times and conditions, P-values were less than 0.008 although the absolute mean Ct when compared showed slight increments and accommodated differences for the detection of MTB and rifampicin resistance. Median values for samples stored at 2-8°C were lower compared to those at room temperature. CONCLUSION: DTS stored at 2-8°C remain more stable for one year compared to higher temperatures and can be consistently used as PT materials in more than one PT round for biannual PT providers.


Assuntos
Mycobacterium tuberculosis , Região de Recursos Limitados , Humanos , Uganda , Ensaio de Proficiência Laboratorial/métodos , Rifampina , Sensibilidade e Especificidade
3.
Arch Pathol Lab Med ; 147(2): 137-142, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35671151

RESUMO

CONTEXT.­: In 2016, the College of American Pathologists (CAP) launched the first next-generation sequencing (NGS) in silico bioinformatics proficiency testing survey to evaluate the performance of clinical laboratory bioinformatics pipelines for the detection of oncology-associated variants at varying allele fractions. This survey focused on 2 commonly used oncology panels, the Illumina TruSeq Amplicon Cancer Panel and the Thermo Fisher Ion AmpliSeq Cancer Hotspot v2 Panel. OBJECTIVE.­: To review the analytical performance of laboratories participating in the CAP NGS bioinformatics (NGSB) surveys, comprising NGSB1 for Illumina users and NGSB2 for Thermo Fisher Ion Torrent users, between 2016 and 2019. DESIGN.­: Responses from 78 laboratories were analyzed for accuracy and associated performance characteristics. RESULTS.­: The analytical sensitivity was 90.0% (1901 of 2112) for laboratories using the Illumina platform and 94.8% (2153 of 2272) for Thermo Fisher Ion Torrent users. Variant type and variant allele fraction were significantly associated with performance. False-negative results were seen mostly for multi-nucleotide variants and variants engineered at variant allele fractions of less than 25%. Analytical specificity for all participating laboratories was 99.8% (9303 of 9320). There was no statistically significant association between deletion-insertion length and detection rate. CONCLUSIONS.­: These results demonstrated high analytical sensitivity and specificity, supporting the feasibility and utility of using in silico mutagenized NGS data sets as a supplemental challenge to CAP surveys for oncology-associated variants based on physical samples. This program demonstrates the opportunity and challenges that can guide future surveys inclusive of customized in silico programs.


Assuntos
Laboratórios , Neoplasias , Humanos , Patologistas , Neoplasias/diagnóstico , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Ensaio de Proficiência Laboratorial/métodos , Biologia Computacional
4.
Arch Pathol Lab Med ; 147(4): 425-433, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35687785

RESUMO

CONTEXT.­: Clinical testing for tumor cell-free DNA (cfDNA) has evolved rapidly, but no practice guidelines exist. OBJECTIVE.­: To summarize cfDNA laboratory practices based on self-reporting and assess preanalytical, analytical, and postanalytical trends that may influence the quality, accuracy, and consistency of cfDNA testing. DESIGN.­: Data were derived from the College of American Pathologists cfDNA proficiency testing program submitted by 101 participating laboratories from 2018 to 2019. RESULTS.­: Most laboratories performing clinical circulating tumor DNA testing are commercial/nonhospital (71.2%; 72 of 101) and international (77.2%; 78 of 101) laboratories. Commercial laboratories had higher monthly test volumes than hospital-based laboratories (median, 36 versus 7-8) and tended to have larger gene panels (median, 50 versus 11 genes) when panel-based testing was offered. The main clinical indications include therapy selection and treatment/disease monitoring. Plasma is the most commonly accepted specimen, which is predominantly collected in cell-stabilizing tubes. Equal proportions of laboratories use next-generation sequencing (NGS) and non-NGS methods to assess key genes, including EGFR, BRAF, KRAS, NRAS, and IDH1. Most laboratories reported a lower limit of detection (LLOD) of 0.5%, variant allele frequency or less, which did not differ by method, NGS or non-NGS, except for EGFR. Sixty-five percent (17 of 26) of laboratories using the US Food and Drug Administration (FDA)-approved non-NGS EGFR assay report analytical sensitivities higher than 0.5%, as compared to 15% (16 of 104) of laboratories using an alternative NGS or non-NGS method. There is also a wider range in LLODs obtained for the FDA-approved EGFR assay than nonapproved assays. CONCLUSIONS.­: These results highlight emerging practice trends and serve as a foundation to initiate future practice recommendations.


Assuntos
Ácidos Nucleicos Livres , Neoplasias , Humanos , Estados Unidos , Ácidos Nucleicos Livres/genética , Patologistas , Mutação , Neoplasias/diagnóstico , Neoplasias/genética , Neoplasias/patologia , Receptores ErbB/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Ensaio de Proficiência Laboratorial/métodos
5.
J AOAC Int ; 106(2): 472-483, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36156140

RESUMO

BACKGROUND: Laboratory sampling is a significant source of error in feed testing. Proficiency testing programs such as the Association of American Feed Control Officials Proficiency Testing Program are an effective means of assessing error in and among analytical methods. However, all proficiency test items are comminuted and blended to control variability among items, effectively minimizing sampling error. Currently there is no mechanism for monitoring sampling error among laboratories. OBJECTIVE: The objective of this work was to investigate the feasibility of a proficiency testing program for laboratory sampling methods and provide insight into a program to advance the performance of sampling in laboratories. METHODS: The study involved the fabrication of identical feed test items from feed ingredients and shipping the uncomminuted materials to volunteer laboratories. The volunteer laboratories followed in-house procedures for selecting test portions for routine feed tests. Tests on all the test portions for a single analyte were performed by a single laboratory, so that the variability in test results could be attributed to laboratory sampling processes to select test portions. RESULTS: The average RSD, %, for Item A and Item B, respectively, were as follows: protein, 5.08 and 5.23; non-protein nitrogen, 8.90 and 16.6; crude fat, 3.45 and 5.67; vitamin A, 33.9 and 26.9; calcium, 21.9 and 23.6; zinc, 17.9 and 27.9; and copper, 17.4 and 27.9. CONCLUSION: This study suggests that a proficiency testing program for laboratory sampling is feasible with manual manufacture of the test items, and data can be used to monitor laboratory sampling proficiency and also to compare the performance of different laboratory sampling methods. HIGHLIGHTS: The data illustrates that each analyte has unique distributional and compositional heterogeneity, thus unique sampling error, even when multiple analytes are determined from a single test portion.


Assuntos
Laboratórios , Ensaio de Proficiência Laboratorial , Estados Unidos , Ensaio de Proficiência Laboratorial/métodos , Manejo de Espécimes , Ração Animal
6.
Appl Immunohistochem Mol Morphol ; 31(7): 452-458, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36194495

RESUMO

Immunohistochemistry (IHC) has for decades been an integrated method within pathology applied to gain diagnostic, prognostic, and predictive information. However, the multimodality of the analytical phase of IHC is a challenge to ensure the reproducibility of IHC, which has been documented by external quality assessment (EQA) programs for many biomarkers. More than 600 laboratories participate in the Nordic immunohistochemical Quality Control EQA program for IHC. In the period, 2017-2021, 65 different biomarkers were assessed and a total of 31,967 results were evaluated. An overall pass rate of 79% was obtained being an improvement compared with 71% for the period, 2003-2015. The pass rates for established predictive biomarkers (estrogen receptor, progesterone receptor, and HER2) for breast carcinoma were most successful showing mean pass rates of 89% to 92%. Diagnostic IHC biomarkers as PAX8, SOX10, and different cytokeratins showed a wide spectrum of pass rates ranging from 37% to 95%, mean level of 75%, and attributed to central parameters as access to sensitive and specific antibodies but also related to purpose of the IHC test and validation performed accordingly to this. Seven new diagnostic biomarkers were introduced, and all showed inferior pass rates compared with the average level for diagnostic biomarkers emphasizing the challenge to optimize, validate, and implement new IHC biomarkers. Nordic immunohistochemical Quality Control operates by "Fit-For-Purpose" EQA principles and for programmed death-ligand 1, 2 segments are offered aligned to the "3-dimensional" approach-bridging diagnostic tests, drugs to be offered, and diseases addressed. Mean pass rates of 65% and 79% was obtained in the 2 segments for programmed death-ligand 1.


Assuntos
Neoplasias da Mama , Ensaio de Proficiência Laboratorial , Humanos , Feminino , Reprodutibilidade dos Testes , Imuno-Histoquímica , Ensaio de Proficiência Laboratorial/métodos , Controle de Qualidade , Receptores de Estrogênio , Neoplasias da Mama/diagnóstico , Biomarcadores Tumorais/análise , Receptor ErbB-2
7.
Arch Pathol Lab Med ; 146(7): 822-832, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34979564

RESUMO

CONTEXT.­: The 2017 Association for Molecular Pathology/American Society of Clinical Oncology/College of American Pathologists (CAP) tier classification guideline provides a framework to standardize interpretation and reporting of somatic variants. OBJECTIVE.­: To evaluate the adoption and performance of the 2017 guideline among laboratories performing somatic next-generation sequencing (NGS). DESIGN.­: A survey was distributed to laboratories participating in NGS CAP proficiency testing for solid tumors (NGSST) and hematologic malignancies (NGSHM). RESULTS.­: Worldwide, 64.4% (152 of 236) of NGSST and 66.4% (87 of 131) of NGSHM participants used tier classification systems, of which the 2017 guideline was used by 84.9% (129 of 152) of NGSST and 73.6% (64 of 87) of NGSHM participants. The 2017 guideline was modified by 24.4% (30 of 123) of NGSST and 21.7% (13 of 60) of NGSHM laboratories. Laboratories implementing the 2017 guideline were satisfied or very satisfied (74.2% [89 of 120] NGSST and 69.5% [41 of 59] NGSHM), and the impression of tier classification reproducibility was high (mean of 3.9 [NGSST] and 3.6 [NGSHM] on a 5-point scale). Of nonusers, 35.2% (38 of 108) of NGSST and 39.4% (26 of 66) of NGSHM laboratories were planning implementation. For future guideline revisions, respondents favored including variants to monitor disease (63.9% [78 of 122] NGSST, 80.0% [48 of 60] NGSHM) and germline variants (55.3% [63 of 114] NGSST, 75.0% [45 of 60] NGSHM). Additional subtiers were not favored by academic laboratories compared to nonacademic laboratories (P < .001 NGSST and P = .02 NGSHM). CONCLUSIONS.­: The 2017 guideline has been implemented by more than 50.0% of CAP laboratories. While most laboratories using the 2017 guideline report satisfaction, thoughtful guideline modifications may further enhance the quality, reproducibility, and clinical utility of the 2017 guideline for tiered somatic variant classification.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala , Neoplasias , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Ensaio de Proficiência Laboratorial/métodos , Patologia Molecular , Reprodutibilidade dos Testes
8.
Arch Pathol Lab Med ; 146(4): 451-461, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34424952

RESUMO

CONTEXT.­: Next-generation sequencing-based assays are increasingly used in clinical molecular laboratories to detect somatic variants in solid tumors and hematologic malignancies and to detect constitutional variants. Proficiency testing data are potential sources of information about challenges in performing these assays. OBJECTIVE.­: To examine the most common sources of unacceptable results from the College of American Pathologists Next-Generation Sequencing Bioinformatics, Hematological Malignancies, Solid Tumor, and Germline surveys and provide recommendations on how to avoid these pitfalls and improve performance. DESIGN.­: The College of American Pathologists next-generation sequencing somatic and germline proficiency testing survey results from 2016 to 2019 were analyzed to identify the most common causes of unacceptable results. RESULTS.­: On somatic and germline proficiency testing surveys, 95.9% (18 815/19 623) and 97.8% (33 890/34 641) of all variants were correctly identified, respectively. The most common causes of unacceptable results related to sequencing were false-negative errors in genomic regions that were difficult to sequence because of high GC content. False-positive errors occurred in the context of homopolymers and pseudogenes. Recurrent errors in variant annotation were seen for dinucleotide and duplication variants and included unacceptable transcript selection and outdated variant nomenclature. A small percentage of preanalytic or postanalytic errors were attributed to specimen swaps and transcription errors. CONCLUSIONS.­: Laboratories demonstrate overall excellent performance for detecting variants in both somatic and germline proficiency testing surveys. Proficiency testing survey results highlight infrequent, but recurrent, analytic and nonanalytic challenges in performing next- generation sequencing-based assays and point to remedies to help laboratories improve performance.


Assuntos
Neoplasias Hematológicas , Neoplasias , Bioensaio , Células Germinativas , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Laboratórios , Ensaio de Proficiência Laboratorial/métodos , Neoplasias/genética
9.
Clin Biochem ; 97: 78-81, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34329621

RESUMO

In the field of laboratory medicine, proficiency testing is a vehicle used to improve the reliability of reported results. When proficiency tests are unavailable for a given analyte, an alternative approach is required to ensure adherence to the International Organization for Standardization (ISO) 15189:2012 standard. In this study, we report the results of a split-sample testing program performed as an alternative to a formal PT. This testing method was based on recommendations provided in the Clinical and Laboratory Standards Institute (CLSI) QMS24 guideline. Two different laboratories measured, in duplicate, the heparan sulfate concentration in five samples using ultra-performance liquid chromatography and tandem mass spectrometry. The data analysis to determine the criterion used for the comparability assessment between the two laboratories was based on Appendix E of the QMS24 guideline. Mean interlaboratory differences fell within the maximum allowable differences calculated from the application of the QMS24 guideline, indicating that the results obtained by the two laboratories were comparable across the concentrations tested. Application of the QMS24 split-sample testing procedure allows laboratories to objectively assess test results, thus providing the evidence needed to face an accreditation audit with confidence. However, due to the limitations of statistical analyses in small samples (participants and/or materials), laboratory specialists should assess whether the maximum allowable differences obtained are suitable for the intended use, and make adjustments if necessary.


Assuntos
Laboratórios Clínicos/normas , Ensaio de Proficiência Laboratorial/métodos , Controle de Qualidade , Cromatografia Líquida/normas , Heparitina Sulfato/análise , Heparitina Sulfato/sangue , Humanos , Espectrometria de Massas em Tandem/normas
10.
Anal Bioanal Chem ; 413(19): 4699-4705, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34120196

RESUMO

This work forms a background to the recent discussion about normal and log-normal distributions in the results of proficiency tests for GMO analysis. In order to clear up some common confusions, the paper first covers some basic principles, viz., a comparison of normally and log-normally distributed samples of results at various precisions, and a background to the determination of assigned values and scoring in proficiency tests. Then follows brief discussions on the identification of outliers and the use of 'tests for normality'. In conclusion, there is a broad outline of the steps that may assist a proficiency testing scheme in deciding on a suitable model of dispersion.


Assuntos
Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/normas , Organismos Geneticamente Modificados , Distribuição Normal , Reprodutibilidade dos Testes
11.
J Clin Lab Anal ; 35(6): e23814, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33948986

RESUMO

BACKGROUND: To utilize the external quality assessment (EQA)/proficiency testing (PT) scheme to evaluate the equivalence of different clinical enzymatic measuring systems in Beijing. METHODS: The Beijing Center for Clinical Laboratory (BCCL) distributed three investigation samples to mutual recognition clinical laboratories in Beijing including alanine aminotransferase (ALT), aspartate aminotransferase (AST), γ-glutamyltransferase (GGT), creatine kinase (CK), and lactate dehydrogenase (LDH). These samples were derived from serum pools with values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) enzymatic reference measurement procedures (RMPs). Each laboratory performed duplicate tests of the samples. Then, the samples at level 1 were used to recalibrate individual measuring systems for repeating the tests. BCCL collected data for evaluation of their analytical quality. RESULTS: Before recalibration, the biases of ALT and AST tests were not traceable to the IFCC RMPs, and the bias pass rates of GGT, CK, and LDH tests were only 51.2%, 55.7%, and 48.6% respectively. After recalibration, the pass rates of ALT, AST, GGT, CK, and LDH increased to 95.1%, 82.9%, 95.1%, 97.1%, and 70.0% respectively. The EQA/PT also showed that after recalibration, more than 95% of laboratories met the optimum level specifications of the biological variation for ALT, AST, GGT, and CK tests and the desirable for LDH tests. CONCLUSION: The enzymatic tests in Beijing need to be further standardized by category 1 or 2 EQA/PT scheme for mutual recognition between clinical laboratories. The criteria of biological variation are more relevant for determining the equivalence of clinical enzymatic tests.


Assuntos
Alanina Transaminase/sangue , Aspartato Aminotransferases/sangue , Ensaios Enzimáticos Clínicos/normas , Creatina Quinase/sangue , L-Lactato Desidrogenase/sangue , Laboratórios/normas , gama-Glutamiltransferase/sangue , Pequim , Serviços de Laboratório Clínico/normas , Humanos , Ensaio de Proficiência Laboratorial/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas
12.
Malar J ; 20(1): 50, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33472640

RESUMO

BACKGROUND: The use of rapid diagnostic tests (RDTs) to diagnose malaria is common in sub-Saharan African laboratories, remote primary health facilities and in the community. Currently, there is a lack of reliable methods to ascertain health worker competency to accurately use RDTs in the testing and diagnosis of malaria. Dried tube specimens (DTS) have been shown to be a consistent and useful method for quality control of malaria RDTs; however, its application in National Quality Management programmes has been limited. METHODS: A Plasmodium falciparum strain was grown in culture and harvested to create DTS of varying parasite density (0, 100, 200, 500 and 1000 parasites/µL). Using the dried tube specimens as quality control material, a proficiency testing (PT) programme was carried out in 80 representative health centres in Togo. Health worker competency for performing malaria RDTs was assessed using five blinded DTS samples, and the DTS were tested in the same manner as a patient sample would be tested by multiple testers per health centre. RESULTS: All the DTS with 100 parasites/µl and 50% of DTS with 200 parasites/µl were classified as non-reactive during the pre-PT quality control step. Therefore, data from these parasite densities were not analysed as part of the PT dataset. PT scores across all 80 facilities and 235 testers was 100% for 0 parasites/µl, 63% for 500 parasites/µl and 93% for 1000 parasites/µl. Overall, 59% of the 80 healthcare centres that participated in the PT programme received a score of 80% or higher on a set of 0, 500 and 1000 parasites/ µl DTS samples. Sixty percent of health workers at these centres recorded correct test results for all three samples. CONCLUSIONS: The use of DTS for a malaria PT programme was the first of its kind ever conducted in Togo. The ease of use and stability of the DTS illustrates that this type of samples can be considered for the assessment of staff competency. The implementation of quality management systems, refresher training and expanded PT at remote testing facilities are essential elements to improve the quality of malaria diagnosis.


Assuntos
Antígenos de Protozoários/análise , Técnicas e Procedimentos Diagnósticos/estatística & dados numéricos , Instalações de Saúde , Mão de Obra em Saúde/normas , Ensaio de Proficiência Laboratorial/normas , Malária Falciparum/diagnóstico , Plasmodium falciparum/química , Humanos , Ensaio de Proficiência Laboratorial/métodos , Controle de Qualidade , Manejo de Espécimes , Togo
13.
J Infect Dev Ctries ; 15(12): 1838-1844, 2021 12 31.
Artigo em Inglês | MEDLINE | ID: mdl-35044941

RESUMO

INTRODUCTION: Proficiency testing (PT) is one of the most valuable and important activities for the Clinical Microbiology Laboratories (CML) to enroll in to ensure the accuracy and reliability of results. This first time conducted nationwide study was warranted to assess the PT performance activity among CML in Lebanon. METHODOLOGY: Four training and PT activities were organized for 110 nationwide laboratories involved in providing clinical microbiology services. In each PT activity, five different bacterial species were distributed to each laboratory to provide identification (ID) and antimicrobial susceptibility testing (AMST) according to prior discussions and guidelines. RESULTS: The percentages of labs that correctly identified the bacterial species and performed the relevant AMST to it, respectively, were as follows: S. aureus, (100% and 67.8%); Enterococcus faecalis (71% and 82%); Listeria monocytogenes (75% and 61%); Streptococcus agalactiae (86% and 71%); Corynebacterium amycolatum (7% and 33 %); Pseudomonas aeruginosa, (93 % and 53.4%); Klebsiella pneumoniae, (97% and 67.7%); Salmonella typhi ESBL (87 % and 66%); Enterobacter aerogenes (89% and 59%) and Stenotrophomonas maltophilia (84 % and 65%). The resistant types for the species were specified by labs as carbapenem resistant (CR) K. pneumoniae in 78 %, CR E. aerogenes in 34 %, MRSA in 83 %, and VRE in 80.5%. CONCLUSIONS: The wide variation as well as the overall humble scoring of accurate results reflects the dire need for the MOPH to establish and maintain a PT activity program, and entrust the reference laboratory to provide continuing education and training sessions.


Assuntos
Laboratórios/normas , Ensaio de Proficiência Laboratorial/métodos , Testes de Sensibilidade Microbiana , Bactérias/isolamento & purificação , Humanos , Líbano , Melhoria de Qualidade
14.
Ann Biol Clin (Paris) ; 78(6): 655-664, 2020 Dec 01.
Artigo em Francês | MEDLINE | ID: mdl-33361016

RESUMO

The lack of quality control for patient point-of-care (POC) INR devices is an issue that has led the French health authorities to make recommendations: a laboratory INR (lab INR) has to be performed at the same time as the POC INR every 6 months. However, the differences observed between the two INRs, POC and lab INRs, are not necessarily due to a failure of the POC INR device. We present here a review of the different causes of discrepancies between INR results, which are the basis of the proposals of the Groupe français d'études sur l'hémostase et la thrombose (GFHT) on the management of lab and POC INR discrepancies. Pre-analytical conditions may account for discrepancies (sampling, transport and storage conditions), as well as analytical factors (mainly the nature of the thromboplastin used) and the clinical context (inflammatory or autoimmune diseases, polycythaemia...). The interpretation of INR discrepancies is not always easy and these proposals aim at standardizing the procedure to be followed in order to make the most appropriate decision for the patient.


Assuntos
Técnicas de Laboratório Clínico/normas , Coeficiente Internacional Normatizado/métodos , Coeficiente Internacional Normatizado/normas , Kit de Reagentes para Diagnóstico/normas , Autoteste , 4-Hidroxicumarinas/uso terapêutico , Anticoagulantes/uso terapêutico , França , Humanos , Indenos/uso terapêutico , Laboratórios/normas , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sociedades Científicas/normas , Trombose/sangue , Trombose/tratamento farmacológico , Vitamina K/antagonistas & inibidores , Vitamina K/uso terapêutico
15.
Malar J ; 19(1): 324, 2020 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-32887612

RESUMO

Microscopy performed on stained films of peripheral blood for detection, identification and quantification of malaria parasites is an essential reference standard for clinical trials of drugs, vaccines and diagnostic tests for malaria. The value of data from such research is greatly enhanced if this reference standard is consistent across time and geography. Adherence to common standards and practices is a prerequisite to achieve this. The rationale for proposed research standards and procedures for the preparation, staining and microscopic examination of blood films for malaria parasites is presented here with the aim of improving the consistency and reliability of malaria microscopy performed in such studies. These standards constitute the core of a quality management system for clinical research studies employing microscopy as a reference standard. They can be used as the basis for the design of training and proficiency testing programmes as well as for procedures and quality assurance of malaria microscopy in clinical research.


Assuntos
Malária/parasitologia , Microscopia/métodos , Testes Diagnósticos de Rotina/métodos , Testes Diagnósticos de Rotina/normas , Humanos , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/normas , Microscopia/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos , Coloração e Rotulagem/normas
16.
BMC Infect Dis ; 20(1): 514, 2020 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-32677988

RESUMO

BACKGROUND: Worldwide, an increase in antimicrobial resistance (AMR) of Neisseria gonorrhoeae has been observed. Until now, no protocol for an external quality assessment (EQA) has been available for Germany. The German gonococcal resistance network (GORENET) performed an EQA of primary laboratories in Germany in order to assess quality of antibiotic susceptibility testing, to gain information about laboratory procedures and to assess the impact of these procedures on test results. METHODS: Laboratories assessed drug susceptibility to cefixime, ceftriaxone, azithromycin, penicillin and ciprofloxacin for five N. gonorrhoeae strains, using their standard laboratory protocols. Minimal inhibitory concentrations (MICs) were compared to World Health Organisation (WHO) consensus results (or, if not available, reference laboratory results), while deviation by +/- one doubling dilution was accepted. Data on laboratory procedures were collected via a standardised questionnaire. Generalized linear models and conditional inference trees (CTREE) were used to assess relationships between laboratory procedures and testing outcomes. RESULTS: Twenty-one primary laboratories participated in the EQA in June 2018. 96% of ciprofloxacin MICs were reported within accepted deviations, as well as 88% for cefixime, 85% for ceftriaxone, 79% for penicillin and 70% for azithromycin. The use of interpretation standards and general laboratory procedures like agar base, incubation settings or the use of control strains strongly differed between laboratories. In statistical analysis, incubation time of cultures < 24 h was associated with correct measurements. Additionally, a 5% CO2 concentration was associated with correct results regarding azithromycin compared to 3%. CTREE analysis showed that incubation time, humidity and CO2 concentration had the greatest influence on the average deviation from consensus results. CONCLUSIONS: In conclusion, we report the development of a protocol for N. gonorrhoeae antimicrobial susceptibility testing in Germany. While testing results were in accordance with the expected consensus results in 70-96%, depending on the antibiotic agent, laboratory methodology was heterogeneous and may significantly affect the testing quality. We therefore recommend the development of a standard operating procedure (SOP) for N. gonorrhoeae susceptibility testing in Germany.


Assuntos
Antibacterianos/uso terapêutico , Farmacorresistência Bacteriana/efeitos dos fármacos , Gonorreia/tratamento farmacológico , Laboratórios/normas , Ensaio de Proficiência Laboratorial , Neisseria gonorrhoeae/efeitos dos fármacos , Antibacterianos/farmacologia , Azitromicina/farmacologia , Azitromicina/uso terapêutico , Cefixima/farmacologia , Cefixima/uso terapêutico , Ceftriaxona/farmacologia , Ceftriaxona/uso terapêutico , Ciprofloxacina/farmacologia , Ciprofloxacina/uso terapêutico , Alemanha , Gonorreia/microbiologia , Humanos , Ensaio de Proficiência Laboratorial/métodos , Testes de Sensibilidade Microbiana , Penicilinas/farmacologia , Penicilinas/uso terapêutico , Controle de Qualidade , Padrões de Referência , Inquéritos e Questionários
17.
J Mol Diagn ; 22(7): 876-884, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32302779

RESUMO

The results of EML4-ALK testing are critical to manage ALK tyrosine kinase receptor inhibitor treatment. Thus, the accurate detection of ALK rearrangement is increasingly becoming a matter of serious concern. To address this issue, a long-term EML4-ALK proficiency testing (PT) scheme was launched in China in 2015, serving as an educational tool for assessing and improving the testing quality of EML4-ALK fusion detection. Responses across 20 different PT samples interrogating three different variants and wild-type samples were collected between 2015 and 2019. Performance was analyzed by evaluating the detection methods, kits, and pre-analytic practices used to further display the landscape of changing conditions of the reliability of EML4-ALK testing. During the 5 years, 3224 results reported from 988 laboratories were evaluated, with an overall error rate of 5.36%. Along with an increasing number of participating laboratories, the error rate within each of the different methods showed a significantly downward trend over the years. No obvious differences in the error rates were found regarding the testing methods or kit manufacturers. Moreover, the individual performance of the laboratories improved when they participated in more PT scheme rounds. The data demonstrated that the performance of individual Chinese laboratories for EML4-ALK testing continuously improved over time by participating PT schemes, regardless of their method. However, care must be taken in standardized operations and validations.


Assuntos
Quinase do Linfoma Anaplásico/genética , Carcinoma Pulmonar de Células não Pequenas/genética , Rearranjo Gênico , Ensaio de Proficiência Laboratorial/métodos , Neoplasias Pulmonares/genética , Proteínas de Fusão Oncogênica/genética , Melhoria de Qualidade , Quinase do Linfoma Anaplásico/antagonistas & inibidores , Animais , Sistemas CRISPR-Cas , Linhagem Celular Tumoral , China/epidemiologia , Feminino , Células HEK293 , Humanos , Hibridização in Situ Fluorescente/métodos , Camundongos , Camundongos Nus , Medicina de Precisão/métodos , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Carga Tumoral/genética , Ensaios Antitumorais Modelo de Xenoenxerto
18.
J Mycol Med ; 30(2): 100970, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32334948

RESUMO

A survey of mycology laboratories for antifungal susceptibility testing (AFST) was undertaken in France in 2018, to better understand the difference in practices between the participating centers and to identify the difficulties they may encounter as well as eventual gaps with published standards and guidelines. The survey captured information from 45 mycology laboratories in France on how they perform AFST (number of strains tested, preferred method, technical and quality aspects, interpretation of the MIC values, reading and interpretation difficulties). Results indicated that 86% of respondents used Etest as AFST method, with a combination of one to seven antifungal agents tested. Most of the participating laboratories used similar technical parameters to perform their AFST method and a large majority used, as recommended, internal and external quality assessments. Almost all the participating mycology laboratories (98%) reported difficulties to interpret the MIC values, especially when no clinical breakpoints are available. The survey highlighted that the current AFST practices in France need homogenization, particularly for MIC reading and interpretation.


Assuntos
Antifúngicos/uso terapêutico , Laboratórios , Testes de Sensibilidade Microbiana , Micologia , Prática Profissional/estatística & dados numéricos , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/métodos , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/normas , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/estatística & dados numéricos , Farmacorresistência Fúngica , França , História do Século XXI , Humanos , Laboratórios/normas , Laboratórios/estatística & dados numéricos , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/estatística & dados numéricos , Testes de Sensibilidade Microbiana/métodos , Testes de Sensibilidade Microbiana/normas , Testes de Sensibilidade Microbiana/estatística & dados numéricos , Micologia/história , Micologia/métodos , Micologia/normas , Micologia/estatística & dados numéricos , Prática Profissional/normas , Controle de Qualidade , Inquéritos e Questionários
19.
Appl Immunohistochem Mol Morphol ; 28(7): 566-570, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32243261

RESUMO

This paper is number 7 in a series developed through a partnership between ISIMM and NordiQC with the purpose of reporting research assessing the performance characteristics of immunoassays in an external proficiency testing program.


Assuntos
Anticorpos Monoclonais/imunologia , Células Epiteliais/metabolismo , Imuno-Histoquímica/métodos , Queratina-5/metabolismo , Ensaio de Proficiência Laboratorial/métodos , Animais , Humanos , Cininogênio de Alto Peso Molecular , Controle de Qualidade
20.
Ann Biol Clin (Paris) ; 78(1): 87-92, 2020 02 01.
Artigo em Francês | MEDLINE | ID: mdl-32108586

RESUMO

Serum proteins and urinary proteins electrophoresis are useful biological tests. They are often prescribed for the screening of monoclonal gammopathys and also during follow-up for treatment response. This test can be accredited according to standard NF ISO 15189 since laboratories use analysers and adapted reagents, but there are numerous protocols for the method validation. This paper present the results of a survey proposed in 2019 to biologists by CNBH and SFBC. The aim of this survey is to give biologists a choice among several protocols that have been positively evaluated by COFRAC.


Assuntos
Acreditação , Análise Química do Sangue/normas , Eletroforese/normas , Laboratórios/normas , Urinálise/normas , Análise Química do Sangue/métodos , Proteínas Sanguíneas/análise , Proteínas Sanguíneas/química , Comportamento de Escolha , Testes Diagnósticos de Rotina/normas , Eletroforese/métodos , Humanos , Ensaio de Proficiência Laboratorial/métodos , Proteinúria/diagnóstico , Proteinúria/urina , Controle de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Inquéritos e Questionários , Urinálise/métodos , Estudos de Validação como Assunto